Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro

Protective relay permanent and transient surges on emission coil - HY

€229.17 Tax included

€189.40 tax excl.

Device for protection against transient and permanent overvoltages in three-phase lines, which acts on an emission coil associated with IGA or molded box.

Associated with a cutting element, it allows protection against permanent overvoltages due to increases in network voltage and transient overvoltages (lightning strikes or switching) in three-phase installations.

Reference: ST-4PB.


Representative image for illustrative purposes, the item supplied will correspond to the specifications indicated.

No queries yet, leave the first!
 

Combined protection device against transient and permanent overvoltages to be associated by means of an emission (trip) coil to a cutting device (IGA) or molded case, in three-phase systems.

The operation of this protection module is to produce a disconnection signal to the main cut-off switch, automatic main switch (IGA) or molded case, when it is subjected to a voltage greater than that which it should receive, in a continuous manner and to derive to ground the transient overvoltages caused by lightning strikes or the switching of electrical distribution lines.

This device, very compact and simple to install, provides very high protection, both against transient or permanent overvoltages, as well as against line overvoltages, by incorporating an IGA (magnetothermic) with a breaking capacity of 10kA. It has a visual indicator of the cutting status.

The supply does not include the circuit breaker or the emission coil, only the surge protector.

technical characteristics:

  • Manufacturer/Supplier: Hyundai Electric
  • Ref: ST-4PB .
  • Nominal voltage UN 240Vac. (N/l1, N/L2, N/L3).
  • Power consumption: 0.6VA.
  • Maximum cable section in terminals: 16 mm 2 (IGA) 6 mm 2 (module).
  • Alarm Contact : 5A / 30VDC, 5A / 250Vac.
  • Protection: IP20.
  • Mounting: DIN 35 rail.
  • Number of DIN modules: 4 (TRIO) 9 (COMBI).
  • Regulations: EN 60898 / EN 50550 / IEC 61643-11.
  • Trigger voltage: 265VAC +/- 2%. (N/L1, N/L2, N/L3).
  • Permanent overvoltage response time:
    • 265Vac: Approximately 7s.
    • 300Vac: Approximately 3s.
    • 350Vac: Approximately 0.5s.
    • 400Vac: Approximately 0.15s.
  • Reset time: 10s.
  • Maximum intensity: 20kA (8/20).
  • Overvoltage response time: according to norm .
  • Standard: IEC61643-11 / EN 61643-11
  • CE marked.

Notes on assembly.

It is mandatory to connect the neutral to terminal N and the ground conductor.

Three-phase transient and permanent overvoltage installation

The thermal-magnetic switch and the emission (trigger) coil are not included in the supply, they must be ordered separately.

For further information you can download the technical sheet by clicking on the "Attached Files" tab.

Professional use material, install in compliance with the regulations in force at the place of installation.

Questions

Be the first to ask a question about this product!

Question about the product

* Required fields
(read)

Responsible: ADAJUSA (CONSTRUCCIONES PBR, S.L.), purpose: Respond to requests for information, legitimacy: consent of the interested party, recipients: data will not be communicated to third parties, rights: Access, rectify and delete data, as well as other rights, as explained in the additional information. (read)